Boiler safety valve used in the Attention

September 14th, 2010

1. Do not calibrate and maintain the required period

Steam Boiler Safety Technology Supervision and Pressure Vessel Safety Technology Supervision is provided that the safety valve testing system should be implemented on a regular basis, usually at least once a year tuning and calibration, while the safety valve when the check of maintenance, to ensure that sensitive and reliable.

Once the take-off safety valve in use, the downturn will be left between the spool and the valve seat layer of water damage, time, will generate a long iron. Did not take off the safety valve sealing surface through long-term use generally will leave some debris, rust and corrosive pollution generated, so that the valve sealing performance.

From the safety valve in terms of the use of management, safety valve should be conducted annually grinding, to check the inspection and maintenance combined. Were found in the extended Unchecked remains widespread.

Continue reading

Application of Bluetooth Technology in Electric Valve Actuator

September 13th, 2010

Abstract: In view of the application of wireless tochnology in electrir valve actuator, this paper analyzes the characteristics of some popular wireless lechnologies and comes up with a solution based on Bluetooth. After analysis of threef forms of the Bluetooth protocol stack, embedded model is chosen to implement Bluetooth wireless communication. The hardware structure and software processes of Bluetooth handheld operating, system are introduced. Remote control of the electric valve actuator with Bluetooth communication module is achieved.

Keywords: electric valve actuator; Bluetooth; KC02

Continue reading

Control Valve Selection

September 13th, 2010

Abstract: A brief introduction of the principle of regulating valve, control valve structure type and choice of control valve flow characteristics and the choice of valve diameter calculation and choice of valve material of choice.

Keywords: control valve; flow characteristics; discharge coefficient

Continue reading

Butterfly valve hydraulic drive unit of fast structure and design

May 25th, 2010

Abstract: The hydraulic drive unit of Fast hydraulic control valve and electrical control part of the series design .

Keywords:Fast off valve;Hydraulic actuator;Series Design

1 Overview

Extraction Steam Turbine Cogeneration can be achieved and widely used in thermal power plant of heating systems to prevent backflow of steam turbine extraction steam piping and condensate back flow , turbine speed caused the accident , the steam turbine extraction steam pipes and electric cut-off valve Check valve be installed between the valve off quickly to instantly cut off the steam pipe to protect the security . As soon shut off butterfly valves for fast (<1s), the output power large (> 100kN), must use the hydraulic drive unit , to adapt to various types of valves , quick closing valve on the hydraulic drive device of the serial design .

Continue reading